We design, install, and support the full spectrum of low-voltage and building technology systems. Serving commercial, industrial, education, healthcare, senior living, and enterprise facilities nationwide.
BICSI-aligned structured cabling infrastructure — CAT6, CAT6A, fiber backbone, and telecom — installed and certified for commercial and institutional facilities across the Southeast US.
Your structured cabling infrastructure is the physical foundation for every IP system in your building — voice, data, Wi-Fi, IP cameras, access control, and building automation all depend on it performing correctly. A cabling plant installed without proper documentation, cable management, or test certification will create network problems that are difficult and expensive to diagnose years later.
JB Technologies designs and installs TIA-568-compliant horizontal cabling, MDF/IDF backbone, and telecom room infrastructure for commercial construction, tenant improvements, and data center builds across Georgia, Tennessee, Alabama, Florida, and the Carolinas. Every installation is tested and certified with a Fluke DSX or comparable tester — and documented so your IT team knows exactly what they have.
We install CAT6 and CAT6A plenum-rated horizontal cabling from the IDF to each work area outlet. Every run is tested end-to-end for compliance with TIA-568 transmission performance standards and labeled per TIA-606. Test reports are provided as part of project closeout.
Telecom rooms are the backbone of your network. We supply and install equipment racks, patch panels, cable managers, power distribution, fiber enclosures, and grounding in both new construction and retrofit environments — organized for long-term maintainability.
Inter-building and inter-floor backbone runs using OS2 single-mode or OM4 multimode fiber depending on distance and bandwidth requirements. Fiber is terminated in LIUs with properly labeled pigtails, and every link is tested with an OLTS for insertion loss compliance.
We support post-occupancy infrastructure changes — adding ports, relocating outlets, repaneling telecom rooms, and resolving legacy cabling issues that are affecting network performance. Every change is tested, labeled, and documented.
Cable plant complexity varies significantly based on building size, floor count, and the density of IP-connected systems. JB Technologies has experience across a full range of commercial building types.
New construction and tenant improvement cabling for Class A office buildings — from single-floor tenants to multi-floor headquarters with centralized IT rooms.
Healthcare facility cabling designed for high port density, clinical equipment connectivity, redundant backbone paths, and compliance with NFPA 99 in patient care areas.
High-density structured cabling for data centers and server rooms — top-of-rack patching, hot aisle/cold aisle cable management, and fiber backbone for storage and core switching.
Industrial facility cabling for barcode scanners, Wi-Fi access points, IP cameras, and VoIP phones — rated for the thermal and environmental conditions of the space.
K-12 and university structured cabling for classrooms, labs, and administrative areas — supporting interactive displays, wireless infrastructure, and building-wide network connectivity.
Hotel structured cabling for guest room connectivity, back-of-house operations, AV systems, and IP camera infrastructure coordinated with the property management system.
All horizontal cabling is tested to TIA-568 standards with a certified tester. Pass/fail results and headroom data are documented for every link and provided as part of project closeout documentation.
We specify the correct cable jacket rating — CMP plenum or CMR riser — for every run based on the space it passes through. No substitutions without documentation.
Every outlet, patch panel port, and cable is labeled per TIA-606 conventions with a consistent naming scheme tied to the as-built drawings — so your IT team can identify any port in seconds.
OS2 single-mode and OM4 multimode fiber installed, fusion spliced, and tested with an OLTS for insertion loss compliance. Splice trays, LIUs, and pigtails are properly organized and labeled.
Every cabling design includes 20% spare capacity in patch panels and conduit fill calculations to accommodate future growth without a full rip-and-replace.
Complete as-built drawings, cable schedules, and test reports delivered at project closeout — giving building owners and IT teams the documentation they need to manage the infrastructure long-term.
Every cabling installation is engineered to comply with the applicable telecommunications standards and building codes.
Telecommunications Cabling Standard — the primary standard governing horizontal cabling, backbone cabling, and telecom room infrastructure requirements.
BICSI Telecommunications Distribution Methods Manual — best practices for system design, installation methods, and pathway routing.
Administration Standard for Telecommunications Infrastructure — governing the labeling, documentation, and record-keeping requirements for cabling installations.
New construction, tenant improvement, or data center build — we'll design a cabling plant that's properly documented and ready to support your network for the long term.
Get a Quote